CX8190-0000
Item number: CX8190-0000
Show gallery
Built-in PC for various Ethernet protocols.
Delivery: Levering 8 - 14 dage
Show gallery
Item number: CX8190-0000
Show gallery
Built-in PC for various Ethernet protocols.
Delivery: Levering 8 - 14 dage
Processor Intel® Celeron® 2000E 2.2 GHCX8190 is a controller with two Ethernet ports, one of which is switched to two RJ45 connectors.
It supports protocols such as real-time Ethernet, ADS UDP / TCP or EtherCAT Automation Protocol (EAP).
K-bus or E-bus terminals can be connected as needed; The CX8190 automatically recognizes the type of I / O system connected during the boot phase.
The control system is programmed with TwinCAT 3 via the fieldbus interface or the additional Ethernet interface.
TwinCAT 3 licenses must be ordered via the TwinCAT 3 price list.24 V DC power supply.
Processor | ARM Cortex ™ -A9, 800 MHz (TC3: 20) | ||
Flash memory slot | microSD card, 512 MB included (expandable) | ||
Main memory | 512 MB DDR3 RAM (not expandable) | ||
Protocol | real-time Ethernet, ADS UDP, ADS TCP, EtherCAT Automation Protocol (EAP) | ||
Programming | TwinCAT 3 | ||
Interface | 1 x RJ45 10/100 Mbit / s, 2 x RJ45 100 Mbit / s (RT Ethernet, intern switch) | ||
Businterface | 2 x RJ45 (changed) | ||
Data transfer rates | 100 Mbit / s | ||
I / O connection | E-bus or K-bus, automatic recognition | ||
Power supply | E-bus / K-bus 2 A | ||
Clock | internal battery-backed clock for time and date (battery behind the front cover, replaceable) | ||
UPS | 1 second UPS | ||
Operating system | Microsoft Windows Embedded Compact 7 | ||
Max. Power course | 4 W (including system interfaces) | ||
Dimensions | (B x H x D) 71 mm x 100 mm x 73 mm | ||
Weight | Approximately 205 g | ||
Operation / storage temperature | -25 ... + 60 ° C / -40 ... + 85 ° C | ||
Relative humidity | 95%, no condensation | ||
Vibration / shock | resistance is in accordance with EN 60068-2-6 / EN 60068-2-27 | ||
EMC immunity | is in accordance with EN 61000-6-2 / EN 61000-6-4 | ||
Protection class | IP 20 | ||
Approvals | CE, UL | ||
TC3 | economics (20); Please see here for an overview of all TwinCAT 3 performances |
This calculator shows the potentially dramatic impact in savings on a robot versus manual labor over the life of the project.
Takes only 1 minute to complete
Our calculator should be seen as an indication. With each installation, there may be other costs / savings that affect the repayment of the individual installation.Total system costs for new automation solution
Number of robots for new solution
Application of solution
Annual labor costs per operator, including employee benefits
Number of operators released per shift
(Note: % part that is released is entered on the next page)Percentage of workforce retained for system operation per shift:
Expected increased productivity
Other savings
Year
Months
Break even
Freed labor over 7 years
Productivity improvement over 7 years